INT 14 - SERIAL I/O - EXTENDED INITIALIZE (CONVERTIBLE,PS)          

Input

Output

AX

04h Break Status RS232 Status Modem Status AX

BX

 Parity Stop Bits     BX

CX

Word Length Baud Rate     CX

DX

 Port Number (0-3)     DX
ES:DI     ES:DI
Break Status:   0 = Break
                1 = No break

Parity:         0 = No parity
                1 = Odd parity
                2 = Even parity
                3 = Stick parity odd
                4 = Stick parity even

Stop Bits:      0 = One stop bit
                1 = Two stop bits (1.5 if 5 bit word length)

Word Length:    0 = 5 bits
                1 = 6 bits
                2 = 7 bits
                3 = 8 bits

Baud Rate:      0 = 110
                1 = 150
                2 = 300
                3 = 600
                4 = 1200
                5 = 2400
                6 = 4800
                7 = 9600
                8 = 19200