INT 68 - APPC/PC - TRANSFER MSG DATA                     

Input

Output

AX

05h       AX

BX

        BX

CX

        CX

 

        DX
DS:DX Control Block   CF
Control Block:

                       12 BYTEs reserved
                          WORD  1C00h
                          BYTE  0 user defined
                                1 NMVT
                                2 alert subvectors
                                3 PDSTATS subvectors
                        5 BYTEs 0
                          DWORD (high  byte  first)  return  code   (see
                                AH=01h)
                       12 BYTEs 0
                          BYTE  if   bit   0  clear,   add   correlation
                                subvector
                                if bit  1  clear,  add  product  set  ID
                                subvector
                                if bit 2 clear, do SYSLOG
                                if bit 3 clear, send SSCP_PU_SESSION
                          BYTE  0
                          WORD  length of data
                        N BYTEs data


Copyright © 1985 to 2022 Beta Systems                            Last modified: Wednesday, January 05, 2022 .