Set upper limit: silent period between rings                   
Func AX 26h
Param DX The number of samples during ring OFF period (140 default)
Return AX None
Delay None
    Set the UPPER LIMIT of the length of the silent period between rings. It
    is not necessary to set this function unless ANSWER_DETECT returns a
    voice detect during a ring. This parameter is set in units of 32msec
    cross count samples (32 msec - 1/32 seconds so 32 samples = 1 second).
    The default of this parameter is 140.  (140 samples = 4 seconds + a
    little) The standard ring tone is 2 seconds on and 4 seconds off. The
    default is also set to detect a PBX ring of 1 second on and 3 seconds
    off.  Adjust this parameter ONLY to adjust for phone equipment that
    does not support the standard