ST-4384E (94186-383H) Wren 5 FH ESDI

       +Data Cable              +Controller Cable     /-5-G-G-12\
      -------- ---             -------------- ---    -| 0 0 0 0 +--
                o o o o o 1-----------+ o o o o o o o +---------+
                o o o o o +Terminator-+ o o o o o o o
                1 2 3 4 5               7 6 5 4 3 2 1
  Motor Start --+ | | | |                        +Drive Selects
option enable     | | | +- Factory use    Note:  There are 2 types of PWA's.
                  | | |    only           One with drive select header on the
       Sectors    | | |                   left, and one with header on the
       -----------+-+-+--                 right (like this). Pin positions
          64      0 0 0                   are the same.
          35      0 0 1 = 329,011,200
          10      0 1 0
          19      0 1 1                0=open; 1=closed
          36      1 0 0 = 338,411,520
          34      1 0 1 = 319,610,880
          87      1 1 0
    Add Mark      1 1 1

                             ST-4384E
                        94186-383H WREN 5 FH

       UNFORMATTED CAPACITY (MB) ________________383
       FORMATTED CAPACITY (34 SECTORS) (MB) _____319 **
       ACTUATOR TYPE ____________________________VOICE COIL
       TRACKS ___________________________________18360
       CYLINDERS ________________________________1224
       HEADS ____________________________________15
       DISCS ____________________________________8
       MEDIA TYPE _______________________________THIN FILM
       RECORDING METHOD _________________________RLL (2,7)
       TRANSFER RATE (mbytes/sec) _______________1.25
       SPINDLE SPEED (RPM) ______________________3,600
       AVERAGE LATENCY (mSEC) ___________________8.33
       INTERFACE ________________________________ESDI
       TPI (TRACKS PER INCH) ____________________1280
       BPI (BITS PER INCH) ______________________19600
       AVERAGE ACCESS (ms) ______________________14.5

       SINGLE TRACK SEEK (ms) ___________________3
       MAX FULL SEEK (ms) _______________________29
       MTBF (power-on hours) ____________________100,000
       POWER REQUIREMENTS: +12V START-UP (amps) _4.5
                           +12V TYPICAL (amps) __2.0
                           +5V START-UP (amps) __1.4
                           +5V TYPICAL (amps) ___0.8
                           TYPICAL (watts) ______23
                           MAXIMUM (watts) ______61
       BUFFERED STEP PULSE RATE (micro sec) _____
       WRITE PRECOMP (cyl) ______________________N/A
       REDUCED WRITE CURRENT (cyl) ______________N/A
       LANDING ZONE (cyl) _______________________AUTO PARK
       IBM AT DRIVE TYPE ________________________*

 * MAY REQUIRE A CONTROLLER WITH BIOS SUPPORT, OR FORMATTING
   AND PARTITIONING SOFTWARE.  ALSO, CHECK TO SEE IF YOUR CMOS SETUP
   HAS A "CUSTOM" OR "USER DEFINABLE" DRIVE TYPE AVAILABLE.

** ESDI controllers which offer an Alternate/Spare sector per track
   option will format to a capacity = Cyl*Hd*(SPT-1)*512 bytes

Seagate reserves the right to change, without notice, product
offerings or specifications. (6/26/90)